Quote from philtao on 27/01/2023, 3:26 pm Hi Andres, Can you confirm the Monitor Firmware version - AHS: version 2.02.08 I can see on the events...
Hi @philtao I think that I have narrowed down the problem. The Victron devices are configured to be controlled externally. The 'CCL' ...
Hi @philtao Thank you for the prompt response. I'll follow the steps this coming weekend and report back Regards Andres
Hi @philtao Thanks you for the details In essence what I'm after is a quick total of the consumed apms over a Period of time. E...
Hi @philtao would I be posible to add another view to look into the actual amperage consumption during a selected timeframe? I am not abl...
Hi guys Thanks for the replies Yes, I already have the TaoBMS, and really happy with it, thus why I was wondering whether there are mode...
Hi @philtao OK, I had to reset the Exception log earlier today, as there were 1000's of errors from previous dates dating back and I could ...
Hi @philtao Yes, both are connected to the shunt I think that this is an overkill, but when I was discussing with the local electrician, he mentio...
Hi @foxy-kitty and @philtao Thanks in advance for the help The battery box hasn't got good ventilation, I will install a vent and a fan this comin...
Hi @philtao Very strange, I have done a Monitor Firmware update and now I can see the chargers working. I have also tried changing on the...
Hi @philtao I am sorry to keep bugging, but there seems to be something wrong with my configuration After enabling the Can-Bus, I do not get the b...