RE: White Hawk - 12V - 920Ah - Alternators with Balmar MC614 regulators, Blue Sky MPPT Solar

Hi John, I will take a closer look at your design and updated triggers/BMS configuration over the weekend, but I would like to comment on your plan ...

Il y a 3 ans
Répondre
RE: What is pre-charge and how it works...

We have a 12V 5000W Quattro inverter/charger that is DC connected to our positive load bus and negative bus. We have no relay on the DC wires as we us...

Il y a 3 ans
Répondre
RE: Foxy Kitty - 12V - 700Ah - 2x Alt + Balmar Reg / 3x Victron MPPT / Superwind 350 + Reg / Victron Quattro

Here is the wiring specification for the new 2P system. I'm updating quite a few things from the current installation to add fuses on the positive wir...

Il y a 3 ans
Répondre
RE: Foxy Kitty - 12V - 700Ah - 2x Alt + Balmar Reg / 3x Victron MPPT / Superwind 350 + Reg / Victron Quattro

Quote from philtao on 26/09/2022, 12:12 pm 1 - For CANbus connectivity, do both monitors need to connect to the Cerbo? Or does only one BMS (the m...

Il y a 3 ans
Répondre
RE: Foxy Kitty - 12V - 700Ah - 2x Alt + Balmar Reg / 3x Victron MPPT / Superwind 350 + Reg / Victron Quattro

Quote from Skokie on 23/09/2022, 5:35 pm Hello Foxy Kitty, thanks for sharing your updates. It’s great to compare and to learn from. For the LED S...

Il y a 3 ans
Répondre
RE: Foxy Kitty - 12V - 700Ah - 2x Alt + Balmar Reg / 3x Victron MPPT / Superwind 350 + Reg / Victron Quattro

Quote from philtao on 17/09/2022, 6:48 pm I now have 500A shunts. The CAN interface is managed by the Monitor, so you need one Monitor for each ba...

Il y a 3 ans
Répondre
RE: Foxy Kitty - 12V - 700Ah - 2x Alt + Balmar Reg / 3x Victron MPPT / Superwind 350 + Reg / Victron Quattro

I'm uploading our documentation for our current system in case they're helpful for others. Let me know if you think I should make one of those pretty ...

Il y a 3 ans
Répondre
RE: Foxy Kitty - 12V - 700Ah - 2x Alt + Balmar Reg / 3x Victron MPPT / Superwind 350 + Reg / Victron Quattro

Update to our on-board charging from diesel engine(s): Removed the diesel generator (too much money to repair and still risk future dodgy behaviou...

Il y a 3 ans
Répondre
RE: SOH calculation looks strange (or very scary)

Quote from Foxy Kitty on 17/09/2022, 12:40 pm @philtao I will check the cell connections again, hopefully that's all it is. Thanks. <edit 20 m...

Il y a 3 ans
Répondre
RE: Shore power charge voltage setting experiments

3 month update: We increased the maximum charging voltage to 13.0V - this provides a SOC ~38%, which handles high AC loads (cooking) much better than ...

Il y a 3 ans
Répondre
RE: SOH calculation looks strange (or very scary)

@philtao I will check the cell connections again, hopefully that's all it is. Thanks. <edit 20 minutes later> No problems with the connection...

Il y a 3 ans
Répondre
RE: Foxy Kitty - 12V - 700Ah - 2x Alt + Balmar Reg / 3x Victron MPPT / Superwind 350 + Reg / Victron Quattro

Quote from philtao on 16/09/2022, 9:54 pm Why would you need two BMV712 to monitor battery voltage, current and SOC? Each BMS will do that for the ...

Il y a 3 ans
Répondre
RE: Foxy Kitty - 12V - 700Ah - 2x Alt + Balmar Reg / 3x Victron MPPT / Superwind 350 + Reg / Victron Quattro

Quote from philtao on 09/09/2022, 7:22 pm Hi Tom, With two batteries (4S2P), to have redundancy, you need to double the contactors, current shunts...

Il y a 3 ans
Répondre
RE: Foxy Kitty - 12V - 700Ah - 2x Alt + Balmar Reg / 3x Victron MPPT / Superwind 350 + Reg / Victron Quattro

Quote from Foxy Kitty on 24/06/2022, 5:24 pm We're thinking of expanding our battery for more capacity. At present, with electric galley and modest ...

Il y a 3 ans