RE: Conflicting charge/discharge parameters when several triggers activate?

Quote from Skokie on 26/08/2022, 6:43 pm Hi Tom, you can give the BMS device a name: open on the GX Touch for the Cerbo Menu ➡️ CAN-bus BMS b...

Il y a 3 ans
Répondre
RE: Conflicting charge/discharge parameters when several triggers activate?

Quote from Skokie on 22/08/2022, 7:02 pm Hi Phil, hi Tom in the VRM Portal of Victron Energy you can observe the current limits. See attachment. ...

Il y a 3 ans
Répondre
RE: Shore power charge voltage setting experiments

Jumped the gun earlier today, here are the edits in the afternoon. After changing the default max charge voltage to 12.8V it took a day and a half b...

Il y a 3 ans
Répondre
RE: Shore power charge voltage setting experiments

Quote from LadyHawk on 28/06/2022, 1:18 pm @foxy-kitty Your dashboard is avaliable on the internet now, Philippe mustve set it up for you. Log ont...

Il y a 3 ans
Répondre
RE: Shore power charge voltage setting experiments

Our battery has stabilised at 42% SOC with the charge voltage set at 13.1V. The Quattro is charging the battery between 5-10A to account for the DC lo...

Il y a 3 ans
Répondre
RE: Settings for Victron Multuiplus Charger

@molly, I'm not an expert and have a Quattro rather than a Multiplus, but I do believe that if you're using CANbus to control charging limits then t...

Il y a 3 ans
Répondre
RE: Foxy Kitty - 12V - 700Ah - 2x Alt + Balmar Reg / 3x Victron MPPT / Superwind 350 + Reg / Victron Quattro

We're thinking of expanding our battery for more capacity. At present, with electric galley and modest other consumers we can go 2 days without chargi...

Il y a 3 ans
Répondre
RE: Cell heating up at different rates

It looks like you have a 2P4S configuration and that you connect your cable terminals to a centre point of the connecting bar with a bolt and not to e...

Il y a 3 ans
Répondre
RE: Definition of „shutdown relays“

Quote from philtao on 08/05/2022, 8:28 am Hi Jens, The "shutdown" feature is a way to activate relay outputs (or deactivate them if they are activ...

Il y a 3 ans
Répondre
RE: Foxy Kitty - 12V - 700Ah - 2x Alt + Balmar Reg / 3x Victron MPPT / Superwind 350 + Reg / Victron Quattro

Quote from andreshs1 on 30/04/2022, 12:58 pm Hi @foxy-kitty Great details, thanks! I think that using the finder relay is a great idea, and I cann...

Il y a 3 ans
Répondre
RE: Foxy Kitty - 12V - 700Ah - 2x Alt + Balmar Reg / 3x Victron MPPT / Superwind 350 + Reg / Victron Quattro

I've made a few changes with my solar arrays and thought I'd document them here as that could help others avoid my initial installation mistakes. Our ...

Il y a 3 ans
Répondre
RE: Let your BMS manage the chargers

Thanks @philtao and @ladyhawk above. While we're connected to shore power continuously (as will be the case for the next few months as we live aboar...

Il y a 3 ans
Page 6 / 8