RE: bms STopped comunicating with monitor and/or PC after firmware update to v1.36

Hello @yachtiritis, If neither the PC nor the Monitor can communicate with the BMS, it seems to be an RS485 connection problem.The problem probably ...

Il y a 1 an
Répondre
RE: écran bloqué

Si l'écran ne répond plus aux interactions utilisateur il se peut que ce soit dû à un plantage du processeur. Il est étonnant qu'un appui prolongé s...

Il y a 1 an
Répondre
RE: écran bloqué

Bonjour Guy, Je me suis permis de déplacer le sujet dans le forum "support utilisateurs". Il y sera plus à sa place. Dans un premier temps pou...

Il y a 1 an
Répondre
RE: New monitor calculations based on incorrect battery capacity

Hi @foxy-kitty, Thanks for the additional information.From what you've described, it doesn't seem that the problem comes from the architecture of yo...

Il y a 1 an
Répondre
RE: New monitor calculations based on incorrect battery capacity

Hello @foxy-kitty,Following an initial analysis of the exported data, several points stand out.The first thing that jumps out is the disparity in char...

Il y a 1 an
Répondre
RE: Multiplus throwing low battery alarm errors - 620amp @ 12v LifePO4 (8 x Prism cells - 2P4S)

Hello Andres,Thanks for your feedback. If I understand correctly, when you draw a large current on your batteries, this generates a temperature differ...

Il y a 1 an
Répondre
RE: New monitor calculations based on incorrect battery capacity

Hi @foxy-kitty,To be able to analyze the situation in more detail, we would need access to your BMS data. The easiest way would be to connect the seco...

Il y a 1 an
Répondre
RE: New monitor calculations based on incorrect battery capacity

Hello @foxy-kitty, For each battery and therefore for each associated TAO BMS : Make sure that the capacity has been correctly defined in the TA...

Il y a 1 an
Répondre
RE: Failed Thermistor?

Glad to hear it. Have a great holiday. François

Il y a 1 an
Répondre
RE: Possible BMS setting for solar always "on"

My mistake. Thank you @foxy-kitty for your comment. It's all about the SOC and not the SoH. I corrected it in my previous message. Concerning the 78...

Il y a 1 an
Répondre
RE: Failed Thermistor?

Hello Stephen, That's good news.We now know what the problem is.I'll contact you by e-mail for the rest.

Il y a 1 an
Répondre
RE: Failed Thermistor?

Thermistors are not connected to fuses. The fact that the fuses are disconnected therefore has no impact on the measurement. It's surprising that yo...

Il y a 1 an
Répondre
RE: Failed Thermistor?

Hello Stephen,Have you tried measuring the resistance on both sides of the connector? There is one side where the contacts are more easily accessible ...

Il y a 1 an
Répondre
RE: Failed Thermistor?

Hello Stephen, In order to be sure that the problem really comes from the cable, it would be necessary for you to measure the resistance that seems ...