RE: SOH calculation looks strange (or very scary)

The resistance of a cell is highly dependent on the SOC. It is roughly the lowest when SOC is somewhere between 40% and 60%, then it goes up when the ...

Il y a 3 ans
Répondre
RE: Foxy Kitty - 12V - 700Ah - 2x Alt + Balmar Reg / 3x Victron MPPT / Superwind 350 + Reg / Victron Quattro

Hi Tom, With two batteries (4S2P), to have redundancy, you need to double the contactors, current shunts and other protective / switching devices. T...

Il y a 3 ans
Répondre
RE: BMS concerning a 2x2P16S bank

Hi @yaq Each group of 4 cells in series will have a different reference voltage (negative of the lowest cell). A BMS Master or Extension is connecte...

Il y a 3 ans
Répondre
RE: BMS concerning a 2x2P16S bank

Hello @yaq, it sounds like you have an interesting projet n front of you. Is it possible to start the base module from the positive pole of the 16...

Il y a 3 ans
Répondre
RE: Conflicting charge/discharge parameters when several triggers activate?

Hi Tom, What you describe is exactly how the system has been designed. The logic is that if there are multiple triggers active at the same time, th...

Il y a 3 ans
Répondre
RE: Balancing in event log

You can check on the Monitor that the cells voltage stay close to one another while charging and the battery gets full. The voltage differential t...

Il y a 3 ans
Répondre
RE: Balancing in event log

Hi Jens, Thanks for your return on the operation of your installation. Yes the balancing activities are logged in the system. You are corre...

Il y a 3 ans
Répondre
RE: White Hawk - 12V - 920Ah - Alternators with Balmar MC614 regulators, Blue Sky MPPT Solar

Hi John, It seems that in "normal" operation the "BlueSea 6006 manual ON-OFF switch" is OFF and the starter battery is charged by the "DuoCharge". ...

Il y a 3 ans
Répondre
RE: Best Connection Points for TAO BMS With 4P4S Pack

Hi John, Your connection points are fine as you have the same number of cells / connections between each voltage tap wire. Therefore when the BMS ...

Il y a 3 ans
Répondre
RE: Mateo - 12v - 400Ah - 4S - Victron MPPT, Orion 48/12

Bonjour Dominique, Si le bateau est à sec et n'a pas besoin d'énergie, le plus conservateur est de charger la batterie à 50% et de tout déconnecter...

Il y a 3 ans
Répondre
RE: Mateo - 12v - 400Ah - 4S - Victron MPPT, Orion 48/12

Bonjour @mateo98, La différence entre la résistance nominale des cellules (renseignée dans les paramètres) et la résistance calculée la plus élevée ...

Il y a 3 ans
Répondre
RE: Tao error messages

Hi Darren, You will find it in the Troubleshooting section, page 44 The BMS manual can be downloaded at that address: Kind regards Philippe

Il y a 3 ans
Répondre
RE: Does the BMS work with the shunt from the BMV-712 Smart?

Hi Leigh, The best to be sure all loads are disconnected is to disconnect on the shunt the cable going to the loads. For the TAO calibration you al...

Il y a 3 ans
Répondre
RE: Mateo - 12v - 400Ah - 4S - Victron MPPT, Orion 48/12

Une fois que le Moniteur sera opérationnel, il est plus pratique d’utiliser l'application web qui regroupe toutes les functionalists de gestion du BMS...

Il y a 3 ans
Répondre
RE: Mateo - 12v - 400Ah - 4S - Victron MPPT, Orion 48/12

La gestion de différents profiles de charges est une fonction du Moniteur et ne peut donc pas se faire avec l'application BMSconfig. se connecter ...

Il y a 3 ans