The conversation was taken off-line... here is the outcome: The exceptions log on the Monitor showed that there was a CAN bus error: canbus/send_msg...
Once you have located your dashboard, copy / paste the IP address to create a shortcut on your PC/device home screen - like that you get to it in one ...
Belle installation - très propre. Je devrais m'en inspirer. Si je comprends bien ta source principale de charge est le solaire avec le chargeur DC/...
You may want to reduce the voltage to start balancing so that you give the BMS enough time to balance... if necessary. I find that starting to balanc...
Andres, can you also confirm the Monitor firmware version (Menu -> About)
Hi Andres, Sorry to hear about the problems you are having. It sounds like some sort of corruption in the firmware / SD card. If you can get the ...
Bonjour @sandrictroy, Il y a plusieurs questions: 1- Est ce que la batterie lithium de 100 Ah peut fournir 55 A en continu?En principe cela ne pos...
Bonjour @mateo98, Pour le MPPT Victron 150/60, le connecteur "Relay" (NO/C/NC) est une sortie. Le connecteur "Remote" est celui à utiliser pour une...
Bonjour @emax, Une tension de charge supérieure à 3.40V est suffisante pour charger une cellule LiFePo4 à 100% avec un temps d'absorption suffisamme...
Regarding the error message displayed on the monitor when selecting the charge profiles menu option: "Error loading charge profiles:....". This erro...
Hi Darren, Yes, if the battery capacity is not set properly the SOC will be wrong. Under the menu option Configuration -> BMS parameters you can...
Andres, I did not realize that your negative cable(s) are not connected directly to cell 1B, but to the link between cells 1A & 1B. It should b...
The main positive battery cable that connects to cell 4 is at the wrong place. It must be connected to the positive terminal of the left cell (the ce...
I confirm that the article from Eric is a must read. Just a few points: No charger is able to stop charging when the lithium battery is full A ...
@skokie You should set the bulk / absorption voltage of the Multiplus (and other chargers) slightly above the 100% SOC voltage set in the BMS. Like...