RE: Using the LRD with Blue Sea ML-series PN770x latching relay

I will answer each of your questions: yes all the power comes from the the "power in" wires (red and black wires with a 2A fuse on the positive wi...

Il y a 3 ans
Répondre
RE: Unable to make changes to CAN bus current and voltage limits using Safari browser

I just tried Safari on iPad and I could change the CANbus charge / discharge limits. Is Safari up to date on your Mac? Has anyone else observed th...

Il y a 3 ans
Répondre
RE: Let your BMS manage the chargers

Reducing charge current with CANbus instructions is a good idea. Reducing the charge voltage is a good way to avoid charging the battery above a cer...

Il y a 3 ans
Répondre
RE: Let your BMS manage the chargers

As you are always connected to shore I guess all the 230V for cooking, computers, TV... comes directly from the shore and does not go through the char...

Il y a 3 ans
Répondre
RE: Karma - Tao - 620AH CATL - Victron Multiplus/ MPPT/ Orion/ Cerbo GX / 120A alternator / Fischer Panda 6kw

Hi Andres, Good to hear that you are progressing on your installation. The "full" voltage is a personal choice. Battery manufacturers say 3.65V p...

Il y a 3 ans
Répondre
RE: Karma - Tao - 620AH CATL - Victron Multiplus/ MPPT/ Orion/ Cerbo GX / 120A alternator / Fischer Panda 6kw

Thanks @foxy-kitty, I could not have said it better - all is correct. Just to summarize: if outputs 1 & 2 are those that control the charger...

Il y a 3 ans
Répondre
RE: Firmware Update Cable

It seems that you are confusing two cables: the USB / RJ11 (or RJ45) cable to connect to the PC / Monitor (supplied with the BMS) - this cable is ...

Il y a 3 ans
Répondre
RE: Does the BMS work with the shunt from the BMV-712 Smart?

A few users have done it and it works fine. If the Victron shunt is 500A / 50mV (the standard one), then its resistance is 100 µOhm. This value has...

Il y a 3 ans
Répondre
RE: Oceane-12v-400AH-ALT 110A-Victron MPPt 30+10A-Chargeur Sterling ProCharge Ultra 40A

Bonjour Michel, As tu pu te connecter au moniteur avant cela? Si oui, qu'est ce qui a changé depuis? Si c'est la première fois, quelle address IP...

Il y a 3 ans
Répondre
RE: Battery Cell Link Drilling

Thanks @skokie for the link to off-grid-garage video. That is very interesting (once he gets into the topic). We can now all understand why it is im...

Il y a 3 ans
Répondre
RE: Battery Cell Link Drilling

I am not sure it will make a big difference as the temperature gradient will not be much on a thick copper link and a short distance. I would drill t...

Il y a 3 ans
Répondre
RE: Use of latching relays

Attached is an example for the connection of the Blue Sea PN770x latching relay using the TAO LRD. Please note that in the past I may have posted (o...

Il y a 3 ans
Répondre
RE: BMS and Monitor firmware updates

These are the only changes made in the v1.31 update, so it is not a critical / security update and there is nothing unsafe about v1.30 firmware. As...

Il y a 3 ans
Répondre
RE: BMS and Monitor firmware updates

BMS firmware v1.31: bug fix: if CCM has disabled the charge and if a trigger activates an additional output, then that output is not deactivated u...

Il y a 3 ans