RE: Replacing my AGM's with Lithium

@andreshs1 The BMS / Monitor sends measures and events data to the Cloud where the full history is kept and can be accessed. To access the BMS/Moni...

Il y a 3 ans
Répondre
RE: Replacing my AGM's with Lithium

@andreshs1: I am not sure how you want to give the instruction to turn on the fridge one day before you go to the boat? the BMS does not know when ...

Il y a 3 ans
Répondre
RE: Replacing my AGM's with Lithium

Hi @andreshs1 I am sure you will understand that I am not in a position to recommend any equipment to fit a specific application as it would engage ...

Il y a 3 ans
Répondre
RE: Replacing my AGM's with Lithium

Sorry, I have no experience with either of these DC/DC chargers. They are both reputable brands. As long as they can provide the required charge cur...

Il y a 3 ans
Répondre
RE: Replacing my AGM's with Lithium

@andreshs1, you have been busy. Well done, that will work. Considering that you have the "standard" alternator designed to charge lead acid batteri...

Il y a 3 ans
Répondre
RE: Avis sur mon schéma d'installation?

Effectivement un by-pass entièrement manuel est le plus sûr pour isoler des circuits. Pour le backup sur la batterie Pb tu auras plusieurs avertiss...

Il y a 3 ans
Répondre
RE: Choix relais

Pas mal comme relais. 0.12 A est très raisonnable (moins de 3 AH par jour). De plus le même relais existe en bistable. Choisir le modèle avec la d...

Il y a 3 ans
Répondre
RE: Replacing my AGM's with Lithium

Hi @andreshs1, Nice looking diagram and very easy to read / understand - this is a good start. First I confirm that the BMS can control the load an...

Il y a 3 ans
Répondre
RE: Choix relais

Ce relais NO (normalement ouvert) semble conçu pour un fonctionnement intermittent et consomme 0.6A!!! Si ce relais est utilisé pour couper la sorti...

Il y a 3 ans
Répondre
RE: Avis sur mon schéma d'installation?

J'ai mis en ligne le schéma que tu m'as envoyé. Oui, les régulateurs solaire MPPT et le convertisseur DC/DC de Victron qui ont une entrée "remote on...

Il y a 3 ans
Répondre
RE: What is pre-charge and how it works...

That will work for a 12 volt installation (actually about 13.2 volt). Pre-charge current will be: 13.2 volt / 8 Ohm = 1.65 A And power dissipated ...

Il y a 3 ans
Répondre
RE: Top Balance

It sounds like the charger itself is drifting and does not keep the constant voltage (maybe due to internal heat) and I would persevere. As long as t...

Il y a 3 ans
Répondre
RE: régulateur d'alternateur

Bonjour Guy, Une batterie lithium a une faible resistance interne et absorbe tout le courant qu'on lui fournit. Les alternateurs vont donc fournir ...

Il y a 3 ans
Répondre
RE: Avis sur mon schéma d'installation?

Le schéma est consistant avec les fonctionnalités du BMS. Il contrôle individuellement les 2 sources de charge (solaire + DC/DC 48v) il contrôle...

Il y a 3 ans
Répondre
RE: Utiliser une batterie plomb comme backup

Il y a une discussion sur ce sujet à la fin de cet article Le première chose à faire est de définir les différentes situations possibles et les act...