I know that by setting both current and voltage at zero it does stop charging. It would make sense that if the instruction to the Cerbo is only zero...
Great! thanks for letting me knowPhilippe
You can only name the relay outputs The triggers are named automatically based on their number and definition. For example on the events log you ca...
Each cell in your battery has a slightly different capacity / internal resistance and these differences will most probably increase over time as each ...
Hi Stephen, You are absolutely right if your intent is to top balance. If you have the TAO Monitor, have a look at the cell voltage history. You...
Hi Andres, Glad to hear the issue seems resolved. Regarding the other problem: Can you confirm that the Monitor itself is OK with a green do...
Hello Andre, If my memory is right you connect to the Victron Cerbo to command Victron equipment. It seems that only three limits are used by Victr...
Hi Andes, I managed to reproduce, found the problem and fixed it in Monitor firmware version 2.02.10. I can no longer reproduce on my system. Can...
Hi Andre, If you check the Monitor manual page 26: "Connect to the Monitor with WiFi" 1.Take note of the Monitor IP address:- if connected to a Wi...
I have tried to reproduce without success, but I observed some strange behavior on the CANbus Charge Current Limit (CCL). I will investigate and get...
Hi Andres, Can you confirm the Monitor Firmware version I can see on the events log that there has been some strange ON then OFF events on 21/01/2...
Hi @andreshs1 I have not seen that behavior before. Here are some steps to diagnose: check the state of the MPPT regulator on the Cerbo console...
Quote from Skokie on 30/11/2022, 7:59 pm Is your battery reaching cell balance condition properly with a voltage of 13.8V. I believe Victron is reco...
Oui, le BMS doit être connecté à la batterie et en marche afin que l'application BMSconfig puisse reconnaître le BMS. Pas de soucis si le BMS n'est ...
Je n'avais pas compris ta question au sujet de la tension, mais en y réfléchissant tu veux peut être dire comment le BMS se configure en 24V? Le BMS...