Thanks for sharing. I will unfortunately have to remove the uploaded file that is copyrighted - I doubt we have permission to have that file on a pub...
Regarding the alternator regulator for LFP you are right. This is what you need: the ability to adjust bulk / absorption voltage a temperature s...
Hi Tom, A 5000 watt inverter must have quite large input capacitors that will generate significant inrush current as soon as it is connected - wheth...
Hi Rick, Very interesting thread on DIYsolar... a bit long and I admit I did not go through the 22 pages! yes, the TAO BMS can control both the ...
Hi John, Battery nominal capacity: You should set the battery nominal capacity to the usable capacity of your battery based on the charge and load...
If you are talking about connecting "via Internet", there is no need to connect the computer to the BMS. All WiFi and Internet connection is handled ...
1 - For CANbus connectivity, do both monitors need to connect to the Cerbo? Or does only one BMS (the master) monitor connect to the Cerbo and the oth...
Quote from yaq on 22/09/2022, 11:32 pm In the case of 2 cells in parallel, rather than connecting the wires of the bms on one of the two terminals o...
Quote from yaq on 22/09/2022, 11:10 pm - So I connect the led panels on the RJ45 and the monitors on the RJ11, Yes then a CAN cable in daisy...
The Monitor and the LED panel do not use the same method to connect to the BMS. The Monitor is a serial communication (RS485) while the LED panel is ...
SOH showed 100% after a few minutes of changing the charging voltage to 13.8V That is quite strange. For the SOH to change the BMS must have reca...
My best guess is that for a while the SOC calculated by the BMS has been out by a significant amount. So when the BMS thought the SOC was within a va...
In normal conditions the cells resistance varies slowly over time and I do not think it can go down - it makes sense that it does only get worse over ...
I now have 500A shunts. The CAN interface is managed by the Monitor, so you need one Monitor for each battery (both BMS are the same and the master ...
Why would you need two BMV712 to monitor battery voltage, current and SOC? Each BMS will do that for the battery it monitors. I think each battery ...